<LOGO>
FM Transmitter Measurement Report
Created: 2026-04-09 17-31-01
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 38 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.5 kHz 78 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 67 kHz 17852 14,3793
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,6 dBr 3,41 dBr 4,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 17:30, 9.04.2026
RT
"YleX Ilta: Sikke & Womma "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6201, 6203, 6207, 6205
FM Scope Max at: 67 kHz MIN: 10 kHz % above 76 kHz: 14,3793 Acquired: 2026/04/09 17.29.55 Total samples: 17852 Equivalent time: 0:14:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 4,8 dBr MIN: -0,6 dBr AVE: 3,41 dBr % above 12,2 dBr: 0,0 Last value: 2,8 dBr (2026/04/09 17.29.54) 17.16 17.18 17.20 17.22 17.24 17.26 17.28 0 2 4 Pm [dBr]